<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href="http://www.blogger.com/styles/atom.css" type="text/css"?><feed xmlns='http://www.w3.org/2005/Atom' xmlns:openSearch='http://a9.com/-/spec/opensearchrss/1.0/' xmlns:georss='http://www.georss.org/georss' xmlns:gd='http://schemas.google.com/g/2005' xmlns:thr='http://purl.org/syndication/thread/1.0'><id>tag:blogger.com,1999:blog-6727360867763117230</id><updated>2011-11-28T13:36:03.656+01:00</updated><category term='fusibles fotovoltaicos PV'/><category term='protección de instalaciones fotovoltaicas'/><category term='bases portafusibles fotovoltaicas'/><category term='bases portafusibles modulares industriales'/><category term='instalaciones fotovoltaicas'/><category term='fusibles para aplicaciones fotovoltaicas'/><category term='proteccion electrica'/><category term='bases portafusibles modulares PMX'/><category term='bases portafusibles para fusibles cilindricos'/><category term='transformadores'/><category term='hannover messe 2009'/><category term='bases portafusibles'/><category term='fusibles'/><category term='feria de material eléctrico'/><category term='jornadas ludicas de proteccion electrica'/><title type='text'>Fusibles, bases y transformadores</title><subtitle type='html'>En el blog de DF ELECTRIC te presentamos las últimas novedades en productos de protección eléctrica: fusibles, bases portafusibles, transformadores, bornes de conexión y tomas de corriente. Te invitamos a que participes opinando sobre los artículos publicados y enviando noticias del sector eléctrico de interés general.</subtitle><link rel='http://schemas.google.com/g/2005#feed' type='application/atom+xml' href='http://df-fusibles.blogspot.com/feeds/posts/default'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6727360867763117230/posts/default?max-results=100'/><link rel='alternate' type='text/html' href='http://df-fusibles.blogspot.com/'/><link rel='hub' href='http://pubsubhubbub.appspot.com/'/><author><name>incade</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='31' height='10' src='http://2.bp.blogspot.com/_1nznTXf7Xn4/TLVdCtiwjyI/AAAAAAAAAEU/WxkMDTztD4g/S220/logo-nextpaint-LR.jpg'/></author><generator version='7.00' uri='http://www.blogger.com'>Blogger</generator><openSearch:totalResults>5</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>100</openSearch:itemsPerPage><entry><id>tag:blogger.com,1999:blog-6727360867763117230.post-3768994961852178386</id><published>2009-09-30T21:55:00.004+02:00</published><updated>2009-09-30T22:04:54.726+02:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='bases portafusibles fotovoltaicas'/><category scheme='http://www.blogger.com/atom/ns#' term='hannover messe 2009'/><category scheme='http://www.blogger.com/atom/ns#' term='bases portafusibles modulares PMX'/><category scheme='http://www.blogger.com/atom/ns#' term='fusibles fotovoltaicos PV'/><category scheme='http://www.blogger.com/atom/ns#' term='feria de material eléctrico'/><category scheme='http://www.blogger.com/atom/ns#' term='instalaciones fotovoltaicas'/><title type='text'>DF Electric en Feria HANNOVER MESSE 2009</title><content type='html'>&lt;span style="color:#666666;"&gt;&lt;strong style="color: rgb(0, 0, 0);"&gt;DF ELECTRIC&lt;/strong&gt;&lt;span style="color: rgb(0, 0, 0);"&gt; ha sido uno de los 6,150 expositores              de 61 paises diferentes en HNNOVER MESSE 2009, la mayor y de mayor              relevancia feria para tecnología industrial. Del 20 al 24 de              Abril, DF ELECTRIC lanzó novedades para la protección              eléctrica y electrónica industrial:&lt;br /&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.df-sa.es/es/blog/uploaded_images/hannover-stand-756077.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 318px;" src="http://www.df-sa.es/es/blog/uploaded_images/hannover-stand-756075.jpg" alt="" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="color:#666666;"&gt;&lt;br /&gt;         &lt;strong style="color: rgb(0, 0, 0);"&gt;RAPIDPLUS gR&lt;/strong&gt;&lt;span style="color: rgb(0, 0, 0);"&gt;. Nueva gama gR que amplia la gama de              los &lt;/span&gt; &lt;span style="color: rgb(0, 0, 0);"&gt;             fusibles para la protección de semiconductores con &lt;/span&gt; &lt;span style="color: rgb(0, 0, 0);"&gt;             características mejoradas.&lt;/span&gt;                            &lt;strong style="color: rgb(0, 0, 0);"&gt;&lt;br /&gt;&lt;br /&gt;Bases portafusibles modulares PMX&lt;/strong&gt;&lt;span style="color: rgb(0, 0, 0);"&gt;.Diseñadas              &lt;/span&gt; &lt;span style="color: rgb(0, 0, 0);"&gt;             para fusibles cilíndricos con múltiples mejoras en sus              &lt;/span&gt; &lt;span style="color: rgb(0, 0, 0);"&gt;             prestaciones que hacen de la nueva gama PMX una de las &lt;/span&gt; &lt;span style="color: rgb(0, 0, 0);"&gt;             mejores bases de su categoría en el mercado.&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.df-sa.es/es/blog/uploaded_images/hannover-pmx-784500.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 376px; height: 400px;" src="http://www.df-sa.es/es/blog/uploaded_images/hannover-pmx-784497.jpg" alt="" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="color:#666666;"&gt;&lt;span style="color: rgb(0, 0, 0);"&gt;&lt;br /&gt;&lt;/span&gt;                            &lt;strong style="color: rgb(0, 0, 0);"&gt;Fusibles y Bases PV&lt;/strong&gt;&lt;span style="color: rgb(0, 0, 0);"&gt;. Estos dos elementos están              destinados &lt;/span&gt; &lt;span style="color: rgb(0, 0, 0);"&gt;             principalmente a ofrecer una solución de protección              compacta, &lt;/span&gt; &lt;span style="color: rgb(0, 0, 0);"&gt;             segura y económica en instalaciones fotovoltaicas.&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.df-sa.es/es/blog/uploaded_images/hannover-pv-737840.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 376px; height: 400px;" src="http://www.df-sa.es/es/blog/uploaded_images/hannover-pv-737834.jpg" alt="" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-weight: bold;"&gt;DF ELECTRIC&lt;/span&gt;&lt;br /&gt;Expertos en protección eléctrica&lt;br /&gt;&lt;br /&gt;más información en &lt;a href="http://www.df-sa.es/"&gt;www.df-sa.es&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6727360867763117230-3768994961852178386?l=df-fusibles.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='related' href='http://www.df-sa.es/' title='DF Electric en Feria HANNOVER MESSE 2009'/><link rel='replies' type='application/atom+xml' href='http://df-fusibles.blogspot.com/feeds/3768994961852178386/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://df-fusibles.blogspot.com/2009/09/df-electric-en-feria-hannover-messe.html#comment-form' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6727360867763117230/posts/default/3768994961852178386'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6727360867763117230/posts/default/3768994961852178386'/><link rel='alternate' type='text/html' href='http://df-fusibles.blogspot.com/2009/09/df-electric-en-feria-hannover-messe.html' title='DF Electric en Feria HANNOVER MESSE 2009'/><author><name>incade</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='31' height='10' src='http://2.bp.blogspot.com/_1nznTXf7Xn4/TLVdCtiwjyI/AAAAAAAAAEU/WxkMDTztD4g/S220/logo-nextpaint-LR.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6727360867763117230.post-1115807388825997831</id><published>2009-09-21T13:24:00.007+02:00</published><updated>2009-09-21T16:57:54.933+02:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='fusibles'/><category scheme='http://www.blogger.com/atom/ns#' term='protección de instalaciones fotovoltaicas'/><category scheme='http://www.blogger.com/atom/ns#' term='fusibles para aplicaciones fotovoltaicas'/><title type='text'>Fusibles para la protección del lado de corriente continua en instalaciones fotovoltaicas</title><content type='html'>&lt;span style="font-weight: bold;"&gt;La creciente preocupación por las elevadas emisiones de CO2 y el impacto que estas tienen en el&lt;/span&gt; &lt;span style="font-weight: bold;"&gt;calentamiento global del planeta ha impulsado en estos últimos años la utilización de las energías renovables. Si bien hace ya bastantes años que se utiliza la energía solar para generar energía eléctrica,ha sido en estos últimos años cuando estas aplicaciones se han desarrollado profundamente, a lo que ha contribuido el marco legal vigente, que ha hecho de estas instalaciones una inversión rentable.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.df-sa.es/es/blog/uploaded_images/fusibles-PV-instalaciones-fotovoltaicas-728373.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 283px;" src="http://www.df-sa.es/es/blog/uploaded_images/fusibles-PV-instalaciones-fotovoltaicas-728370.jpg" alt="" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;Estas instalaciones han ido creciendo en potencia y mejorando tecnológicamente y, en esta evolución, han aparecido nuevas necesidades de protección, especialmente en la parte de corriente continua(DC), donde debido al constante incremento de potencia de las plantas destinadas a ser conectadas a la red, es común que se alcancen tensiones superiores a los 800V DC. Atentos a estas nuevas necesidades, DF Electric ha desarrollado una gama de cartuchos fusibles y sus correspondientes bases portafusibles, especialmente diseñadas para las condiciones en que tienen que trabajar y actuar estas protecciones.&lt;br /&gt;&lt;br /&gt;&lt;span style="font-weight: bold;"&gt;Estructura básica de una instalación fotovoltaica conectada a la red&lt;/span&gt;&lt;br /&gt;En una instalación fotovoltaica (PV) la generación de energía se produce mediante la transformación de la luz solar en energía eléctrica (corriente continua), función realizada por las células fotovoltaicas, agrupadas en módulos, que a su vez son conectados en serie para sumar las tensiones formando grupos (strings). Varios de estos grupos se conectan en paralelo para sumar las corrientes. En este punto ya tenemos una gran potencia en corriente continua que se debe convertir a corriente alterna, función que realiza el inversor. Ya en la parte de corriente alterna tenemos las correspondientes protecciones, los equipos de medida destinados a cuantificar la energía aportada a la red y la aparamenta necesaria para realizar la conexión.&lt;br /&gt;&lt;br /&gt;La instalación se complementa con las correspondientes protecciones contra las sobretensiones transitorias, tanto en la parte de continua como en la de alterna, diversos seccionadores que permiten cortar algunas secciones de la instalación para tareas de mantenimiento.&lt;br /&gt;&lt;br /&gt;El material instalado en la parte de corriente alterna, es el normalmente utilizado en las instalaciones de baja tensión, sin embargo, es en la parte de corriente continua donde debido a las especiales condiciones de trabajo se han tenido que desarrollar materiales y componentes específicos para este tipo de instalaciones, desde cables hasta protectores de sobretensiones, seccionadores y lógicamente unos fusibles de protección adecuados.&lt;br /&gt;&lt;br /&gt;Como las células fotovoltaicas cuando son cortocircuitadas aportan bajas corrientes de defecto, aquellas instalaciones pequeñas que tengan como máximo tres grupos (strings) de módulos fotovoltaicos, no es necesario que sean protegidas contra sobrecorrientes. A partir de cuatro deben protegerse siempre.&lt;br /&gt;&lt;br /&gt;&lt;span style="font-weight: bold;"&gt;Protección contra sobrecargas y cortocircuitos en la parte de corriente continua&lt;/span&gt;&lt;br /&gt;En la parte de corriente continua las condiciones de trabajo tienen unas peculiaridades que hacen que la protección sea mucho más compleja:&lt;br /&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt;Corriente continua (DC): Es más difícil la interrupción de la corriente continua que la alterna. El hecho de que no pase por cero dificulta la extinción del arco en el interior del fusible (especialmente con corrientes débiles). La constante detiempo a considerar en la práctica es muy baja (del orden de L/R ≈ 1 ms) ya que la única inductancia del circuito es prácticamente la de los cables.&lt;br /&gt;&lt;/li&gt;&lt;/ul&gt;&lt;ul&gt;&lt;li&gt;Valores elevados de tensión: Con la finalidad de aumentar la potencia de las instalaciones y mejorar el rendimiento del sistema, se trabaja a tensiones elevadas (cerca de 900 V DC). Esto además posibilita que los inversores puedan trabajar sin transformador lo que redunda en un mejor rendimiento y en una reducción de costes.&lt;br /&gt;&lt;/li&gt;&lt;/ul&gt;&lt;ul&gt;&lt;li&gt;Corrientes de defecto débiles: Las células fotovoltaicas cuando son cortocircuitadas aportan bajas corrientes de defecto, por lo que los fusibles para esta aplicación (PV) deben ser capaces de interrumpir sobrecorrientes débiles. Estas condiciones, sumadas a que es corriente continua y con valores de de tensión elevados hacen que el fusible deba trabajar en condiciones muy difíciles.&lt;br /&gt;&lt;/li&gt;&lt;/ul&gt;&lt;ul&gt;&lt;li&gt;Variación constante de corriente: Los ciclos día/noche y el paso de nubes hacen que la corriente varíe continuamente a través de los fusibles, generando continuos calentamientos y enfriamientos que producen stress térmico y mecánico en los materiales, especialmente en el elemento de fusión. &lt;/li&gt;&lt;/ul&gt;Si el fusible no está preparado para ello, se produce un envejecimiento prematuro que provoca la fusión intempestiva del mismo, con la consiguiente desconexión del grupo de módulos, la pérdida de potencia generada y la necesidad de intervenir para la reposición del mismo, con los perjuicios económicos que se derivan.&lt;br /&gt;&lt;br /&gt;Por todos estos motivos, no deben utilizarse fusibles de uso general gG en la parte de DC, ya que no cumplen los requisitos para estas instalaciones y en caso de defecto no pueden interrumpir la corriente de forma segura, con resultados catastróficos para el resto de la instalación y para las personas.&lt;br /&gt;&lt;br /&gt;DF Electric ha desarrollado una gama de cartuchos fusibles y sus correspondientes bases portafusibles, especialmente diseñadas para las condiciones en que tienen que trabajar y actuar estas protecciones.&lt;br /&gt;&lt;br /&gt;Los cartuchos fusibles son cilíndricos de tamaño 10x38, que es una talla muy generalizada para esta aplicación y suelen montarse en bases portafusibles modulares con grado de protección IP20. Estas bases deben estar diseñadas para poder trabajar a los niveles de tensión requeridos en cuanto a materiales, líneas de fuga y distancias de aislamiento.&lt;br /&gt;&lt;br /&gt;&lt;span style="font-weight: bold;"&gt;Instalación y selección de la protección del lado de DC&lt;/span&gt;&lt;br /&gt;A menudo, a proyectistas e instaladores les surgen dudas acerca de cómo deben seleccionarse estas protecciones. Unos criterios básicos para la correcta aplicación de este tipo de protección serían los siguientes:&lt;br /&gt;&lt;br /&gt;En cada grupo de módulos deben colocarse dos fusibles, uno en la polaridad negativa y otro en la negativa.&lt;br /&gt;&lt;br /&gt;Si partimos de la base que utilizamos fusibles específicos para este tipo de instalaciones, los dos parámetros básicos a tener en cuenta para una correcta selección serán la tensión y la corriente asignada.&lt;br /&gt;&lt;br /&gt;Para determinar la tensión asignada mínima del fusible debemos considerar los siguientes datos:&lt;br /&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt; Tensión de circuito abierto de los módulos PV (V&lt;span style="font-size:78%;"&gt;OC&lt;/span&gt; STC)&lt;/li&gt;&lt;li&gt; Número de módulos conectados en serie (M).&lt;/li&gt;&lt;li&gt; Factor de seguridad (al menos 10%).&lt;/li&gt;&lt;/ul&gt;&lt;br /&gt;Así, la tensión asignada en DC mínima de los fusibles será:&lt;br /&gt;&lt;br /&gt;    &lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.df-sa.es/es/blog/uploaded_images/formula01-761383.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 240px; height: 50px;" src="http://www.df-sa.es/es/blog/uploaded_images/formula01-761378.jpg" alt="" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;La tensión de circuito abierto de los módulos V&lt;span style="font-size:78%;"&gt;OC&lt;/span&gt; (STC) es la tensión máxima que un módulo fotovoltaico puede dar cuando funciona en vacío (sin ninguna carga conectada) en unas condiciones de ensayo determinadas (STC = &lt;span style="font-style: italic;"&gt;Standard Test Condition&lt;/span&gt;) y es un dato indicado por el fabricante de los módulos fotovoltaicos. Para escoger la corriente asignada del fusible, los puntos a contemplar serán:&lt;br /&gt;&lt;br /&gt;&lt;ul&gt;&lt;li&gt; Intensidad de cortocircuito de los módulos ISC (STC)&lt;/li&gt;&lt;li&gt; Factor de corrección por variación de la corriente.&lt;/li&gt;&lt;li&gt; Factor de corrección de la temperatura ambiente.&lt;/li&gt;&lt;/ul&gt;La intensidad de cortocircuito de los módulos I&lt;span style="font-size:78%;"&gt;SC&lt;/span&gt; (STC) es la corriente máxima que un módulo fotovoltaico puede dar en unas condiciones de ensayo determinadas y es un dato indicado por el fabricante de los módulos fotovoltaicos.&lt;br /&gt;&lt;br /&gt;Dadas las condiciones de funcionamiento de este tipo de instalaciones, debemos aplicar un factor de corrección por variación de la corriente (recomendado 0,85).&lt;br /&gt;&lt;br /&gt;La temperatura ambiente en el interior de las cajas puede alcanzar fácilmente valores de 40ºC ó 45ºC (para climas tropicales hay que considerar incluso valores más elevados) y esto afecta al funcionamiento del cartucho fusible. Así si tomamos como referencia el valor de 45ºC se debe aplicar un factor de corrección de aproximadamente 0,90.&lt;br /&gt;&lt;br /&gt;Con las consideraciones anteriores, la corriente asignada del fusible deberá ser:&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.df-sa.es/es/blog/uploaded_images/formula02-722504.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 307px; height: 82px;" src="http://www.df-sa.es/es/blog/uploaded_images/formula02-722498.jpg" alt="" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-weight: bold;"&gt;Miquel Pérez&lt;/span&gt;&lt;br /&gt;Jefe de Laboratorio&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;DF ELECTRIC&lt;br /&gt;Expertos en protección eléctrica&lt;br /&gt;&lt;br /&gt;más información en &lt;a href="http://www.df-sa.es/"&gt;www.df-sa.es&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6727360867763117230-1115807388825997831?l=df-fusibles.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='related' href='http://www.df-sa.es/es/fusibles/fusibles-cilindricos/fusibles-cilindricos-gR.html' title='Fusibles para la protección del lado de corriente continua en instalaciones fotovoltaicas'/><link rel='replies' type='application/atom+xml' href='http://df-fusibles.blogspot.com/feeds/1115807388825997831/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://df-fusibles.blogspot.com/2009/09/fusibles-para-la-proteccion-del-lado-de.html#comment-form' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6727360867763117230/posts/default/1115807388825997831'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6727360867763117230/posts/default/1115807388825997831'/><link rel='alternate' type='text/html' href='http://df-fusibles.blogspot.com/2009/09/fusibles-para-la-proteccion-del-lado-de.html' title='Fusibles para la protección del lado de corriente continua en instalaciones fotovoltaicas'/><author><name>incade</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='31' height='10' src='http://2.bp.blogspot.com/_1nznTXf7Xn4/TLVdCtiwjyI/AAAAAAAAAEU/WxkMDTztD4g/S220/logo-nextpaint-LR.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6727360867763117230.post-5541131999956913074</id><published>2009-06-05T10:12:00.006+02:00</published><updated>2009-06-05T12:02:49.941+02:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='proteccion electrica'/><category scheme='http://www.blogger.com/atom/ns#' term='fusibles'/><category scheme='http://www.blogger.com/atom/ns#' term='bases portafusibles'/><category scheme='http://www.blogger.com/atom/ns#' term='transformadores'/><category scheme='http://www.blogger.com/atom/ns#' term='jornadas ludicas de proteccion electrica'/><title type='text'>Jornadas lúdicas de protección eléctrica</title><content type='html'>El pasado 16 de abril tuvimos la visita de los alumnos de &lt;span style="font-weight: bold;"&gt;1º Curso de Grado Medio, Especialidad Electricidad&lt;/span&gt;, de la &lt;span style="font-weight: bold;"&gt;Escola Pia de Mataró&lt;/span&gt;.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.df-sa.es/es/blog/uploaded_images/visita-escolas-pias-784780.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 300px;" src="http://www.df-sa.es/es/blog/uploaded_images/visita-escolas-pias-784763.jpg" alt="" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;La sesión tuvo el siguiente orden:&lt;br /&gt;&lt;br /&gt;1) Recepción, Presentaciones y Despedida, a cargo de &lt;span style="font-weight: bold;"&gt;Javier Ortega&lt;/span&gt;, Responsable de Recursos Humanos.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.df-sa.es/es/blog/uploaded_images/visita-escolas-pias01-757908.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 300px;" src="http://www.df-sa.es/es/blog/uploaded_images/visita-escolas-pias01-757894.jpg" alt="" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;2) Presentación técnica gama Productos y visita a departamentos de I+D y Laboratorio, a cago de &lt;span style="font-weight: bold;"&gt;Josep Durante&lt;/span&gt;, Responsable de I+D+I y de &lt;span style="font-weight: bold;"&gt;Miquel Pérez&lt;/span&gt; y &lt;span style="font-weight: bold;"&gt;José Luis Gregorio&lt;/span&gt;, Responsable y colaborador de Laboratorio.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.df-sa.es/es/blog/uploaded_images/visita-escolas-pias04-772513.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 300px;" src="http://www.df-sa.es/es/blog/uploaded_images/visita-escolas-pias04-772498.jpg" alt="" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.df-sa.es/es/blog/uploaded_images/visita-escolas-pias02-726873.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 300px;" src="http://www.df-sa.es/es/blog/uploaded_images/visita-escolas-pias02-726870.jpg" alt="" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;3) Presentación procesos y líneas de Producción, a cargo de &lt;span style="font-weight: bold;"&gt;Jordi Molero&lt;/span&gt;, Responsable de procesos.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.df-sa.es/es/blog/uploaded_images/visita-escolas-pias03-780002.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 300px;" src="http://www.df-sa.es/es/blog/uploaded_images/visita-escolas-pias03-779999.jpg" alt="" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;4) Reportaje Gráfico, &lt;span style="font-weight: bold;"&gt;Víctor Ruiz&lt;/span&gt;, colaborador de Recursos Humanos .&lt;br /&gt;&lt;br /&gt;La visita se realizó según lo previsto. Nos visitaron 17 alumnos y 1 tutor. Los cuales se involucraron en la exposición y mostrando su atención e interés durante toda la visita.&lt;br /&gt;&lt;br /&gt;Todos ellos pudieron comprobar la metodología de trabajo en DF Electric, una empresa de referencia mundial en la fabricación de &lt;a href="http://www.df-sa.es/es/fusibles/fusibles-industriales.html"&gt;fusibles&lt;/a&gt;, &lt;a href="http://www.df-sa.es/es/bases-portafusibles/bases-portafusibles.html"&gt;bases portafusibles&lt;/a&gt;, &lt;a href="http://www.df-sa.es/es/transformadores/transformadores.html"&gt;transformadores&lt;/a&gt; y demás accesorios de protección eléctrica y electrónica industrial.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;DF ELECTRIC&lt;br /&gt;&lt;a href="http://www.df-sa.es/"&gt;Expertos en protección eléctrica&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;más información en &lt;a href="http://www.df-sa.es/"&gt;www.df-sa.es&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6727360867763117230-5541131999956913074?l=df-fusibles.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='related' href='http://www.df-sa.es/' title='Jornadas lúdicas de protección eléctrica'/><link rel='replies' type='application/atom+xml' href='http://df-fusibles.blogspot.com/feeds/5541131999956913074/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://df-fusibles.blogspot.com/2009/06/jornadas-ludicas-de-proteccion.html#comment-form' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6727360867763117230/posts/default/5541131999956913074'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6727360867763117230/posts/default/5541131999956913074'/><link rel='alternate' type='text/html' href='http://df-fusibles.blogspot.com/2009/06/jornadas-ludicas-de-proteccion.html' title='Jornadas lúdicas de protección eléctrica'/><author><name>incade</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='31' height='10' src='http://2.bp.blogspot.com/_1nznTXf7Xn4/TLVdCtiwjyI/AAAAAAAAAEU/WxkMDTztD4g/S220/logo-nextpaint-LR.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6727360867763117230.post-199416468912333094</id><published>2009-05-25T14:18:00.010+02:00</published><updated>2009-05-26T21:45:29.672+02:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='proteccion electrica'/><category scheme='http://www.blogger.com/atom/ns#' term='bases portafusibles modulares industriales'/><category scheme='http://www.blogger.com/atom/ns#' term='bases portafusibles para fusibles cilindricos'/><title type='text'>Bases portafusibles modulares PMX</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.df-sa.es/es/blog/uploaded_images/PMX-identificacion-708027.jpg"&gt;&lt;/a&gt;&lt;span style="font-weight: bold;"&gt;DF ELECTRIC&lt;/span&gt; lanza su nueva bases portafusibles modulares para fusibles cilíndricos talla 22x58.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;div&gt;&lt;span class="Apple-style-span" style="color: rgb(0, 0, 238);"&gt;&lt;img src="http://www.df-sa.es/es/blog/uploaded_images/base-portafusibles-pmx-706356.jpg" alt="" style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 384px;" border="0" /&gt;&lt;/span&gt;&lt;br /&gt;Las principales características que ofrece esta nueva base portafusibles PMX son:&lt;br /&gt;&lt;br /&gt;&lt;span style="font-size:180%;"&gt;·&lt;/span&gt;  Amplia y variada gama de versiones con indicador y microrruptor. 690V, 24V DC, Microruptor PRECORTE-PRESENCIA-FUSION y SOLO FUSIÓN&lt;br /&gt;&lt;span style="font-size:180%;"&gt;·&lt;/span&gt; Disponible accesorio para bloqueo de la base mediante candado.&lt;br /&gt;&lt;span style="font-size:180%;"&gt;·&lt;/span&gt; Accesorio de seguridad IP20 en zona bornes. Para cables de sección inferiores a 10 mm2&lt;br /&gt;&lt;span style="font-size:180%;"&gt;·&lt;/span&gt; Todas las versiones van equipadas con porta etiquetas para la identificación del circuito.&lt;br /&gt;&lt;span style="font-size:180%;"&gt;·&lt;/span&gt; Diseño más compacto.&lt;br /&gt;&lt;span style="font-size:180%;"&gt;·&lt;/span&gt; Unión multipolar mediante accesorios para bases y microrruptores.&lt;br /&gt;&lt;span style="font-size:180%;"&gt;·&lt;/span&gt; Zonas de ventilación optimizadas para una mejor disipación del calor&lt;br /&gt;&lt;span style="font-size:180%;"&gt;·&lt;/span&gt; Fijación a rail DIN de 2 posiciones preparada para herramienta tipo "pala" y "clase pz"&lt;br /&gt;&lt;span style="font-size:180%;"&gt;·&lt;/span&gt; Fabricada en polímero de altas prestaciones con una temperatura de fusión superior a 300 ºC. Esto ofrece un margen de seguridad mayor frente a un posible sobrecalentamiento del cartucho.&lt;br /&gt;&lt;span style="font-size:180%;"&gt;·&lt;/span&gt; La base PMX permite manipular la fijación rail DIN con la misma herramienta que el instalador usa para el embornado, indistintamente si es punta en forma de ranura o PZ2.&lt;br /&gt;&lt;span style="font-size:180%;"&gt;·&lt;/span&gt; La base PMX está fabricada con materiales plásticos libres de halógenos, preparados para las&lt;br /&gt;futuras restricciones sobre estas sustancias.&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;div&gt;&lt;br /&gt;&lt;/div&gt;&lt;div&gt;&lt;span class="Apple-style-span" style="color: rgb(0, 0, 238);"&gt;&lt;img src="http://www.df-sa.es/es/blog/uploaded_images/PMX-microrruptor-778509.jpg" alt="" style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 244px;" border="0" /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span class="Apple-style-span" style="color: rgb(0, 0, 238);"&gt;&lt;span class="Apple-style-span" style="color: rgb(0, 0, 0);"&gt;&lt;br /&gt;&lt;/span&gt;&lt;img src="http://www.df-sa.es/es/blog/uploaded_images/PMX-candado-730012.jpg" alt="" style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 242px;" border="0" /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;div style="text-align: center;"&gt;&lt;span class="Apple-style-span" style="color: rgb(0, 0, 238);"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div style="text-align: center;"&gt;&lt;span class="Apple-style-span" style="color: rgb(0, 0, 238);"&gt;&lt;img src="http://www.df-sa.es/es/blog/uploaded_images/PMX-identificacion-708025.jpg" alt="" style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 241px;" border="0" /&gt;&lt;/span&gt;&lt;/div&gt;&lt;div style="text-align: left;"&gt;&lt;span class="Apple-style-span" style="color: rgb(0, 0, 238);"&gt;&lt;span class="Apple-style-span" style="font-weight: bold;"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;&lt;span class="Apple-style-span" style="font-weight: bold;"&gt;Todas estas prestaciones hacen de la nueva Base PMX uno de los productos más completos del mercado.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;div&gt;&lt;br /&gt;&lt;span class="Apple-style-span" style="font-weight: bold;"&gt;DF ELECTRIC&lt;br /&gt;&lt;/span&gt;&lt;a href="http://www.df-sa.es/es/"&gt;Expertos en protección eléctrica&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;más información en &lt;a href="http://www.df-sa.es/es/"&gt;www.df-sa.es&lt;/a&gt;&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6727360867763117230-199416468912333094?l=df-fusibles.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='related' href='http://www.df-sa.es/es/bases/bases-cilindricos/bases-cilindricos-PMX.html' title='Bases portafusibles modulares PMX'/><link rel='replies' type='application/atom+xml' href='http://df-fusibles.blogspot.com/feeds/199416468912333094/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://df-fusibles.blogspot.com/2009/05/bases-portafusibles-modulares-pmx.html#comment-form' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6727360867763117230/posts/default/199416468912333094'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6727360867763117230/posts/default/199416468912333094'/><link rel='alternate' type='text/html' href='http://df-fusibles.blogspot.com/2009/05/bases-portafusibles-modulares-pmx.html' title='Bases portafusibles modulares PMX'/><author><name>incade</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='31' height='10' src='http://2.bp.blogspot.com/_1nznTXf7Xn4/TLVdCtiwjyI/AAAAAAAAAEU/WxkMDTztD4g/S220/logo-nextpaint-LR.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6727360867763117230.post-8194665202891289231</id><published>2009-03-02T19:08:00.014+01:00</published><updated>2009-05-26T21:19:55.025+02:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='proteccion electrica'/><category scheme='http://www.blogger.com/atom/ns#' term='fusibles'/><category scheme='http://www.blogger.com/atom/ns#' term='bases portafusibles'/><category scheme='http://www.blogger.com/atom/ns#' term='instalaciones fotovoltaicas'/><title type='text'>Fusibles y Bases portafusibles para aplicaciones fotovoltaicas</title><content type='html'>&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.df-sa.es/es/blog/uploaded_images/energia-fotovoltaica-749713.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 400px; height: 265px;" src="http://www.df-sa.es/es/blog/uploaded_images/energia-fotovoltaica-749700.jpg" alt="" border="0" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span style="font-size:130%;"&gt;&lt;span style="font-weight: bold;"&gt;LA ENERGIA FOTOVOLTAICA&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;La Energía Fotovoltaica es la energía solar que utiliza células fotovoltaicas solares o matrices para convertir la luz del sol directamente en electricidad.&lt;br /&gt;&lt;br /&gt;La Energía Fotovoltaica es también el campo de estudio más desarrollado actualmente y existen muchos institutos de investigación dedicados a trabajar en este tipo de energía.&lt;br /&gt;&lt;br /&gt;Debido al crecimiento la necesidad de energía fotovoltaica, la fabricación de células fotovoltaicas se ha ampliado notablemente en los últimos años. La producción de energía fotovoltaica se ha duplicado cada dos años, ha aumentado en un promedio del 48 por ciento cada año desde 2002, por lo que es la energía que más rápido crecimiento ha sufrido del mundo. A finales de 2007, según datos preliminares, la producción mundial acumulada fue 12400 megavatios.&lt;br /&gt;&lt;br /&gt;Los incentivos financieros, como los de alimentación preferencial en las tarifas de la electricidad generada por energía solar y medición neta, han apoyado las instalaciones de energía solar fotovoltaica en muchos países, entre ellos Alemania, Japón, y los Estados Unidos, haciendo que este mercado aumente considerablemente.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://www.df-sa.es/es/blog/uploaded_images/instalaciones-fotovoltaicas-773859.jpg"&gt;&lt;img style="margin: 0px auto 10px; display: block; text-align: center; cursor: pointer; width: 381px; height: 400px;" src="http://www.df-sa.es/es/blog/uploaded_images/instalaciones-fotovoltaicas-773856.jpg" alt="" border="0" /&gt;&lt;/a&gt;&lt;span style="font-size:130%;"&gt;&lt;span style="font-weight: bold;"&gt;SOLUCIONES PARA INSTALACIONES FOTOVOLTAICAS&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;DF ELECTRIC lanza al mercado una nueva base portafusible modular y fusibles Pv para instalaciones fotovoltaicas.&lt;br /&gt;&lt;br /&gt;La principal novedad que ofrecen estos productos es la tensión asignada de 1000 V DC, en caso de la base y los 900 V DC del fusible. Estos dos elementos están destinados principalmente a ofrecer una solución de protección compacta, segura y económica en instalaciones fotovoltaicas, donde, debido al constante incremento de potencia y la evolución tecnológica, es común que se precise proteger grupos de paneles solares que pueden alcanzar tensiones de hasta 900 V DC.&lt;br /&gt;&lt;br /&gt;Los fusibles por otra parte también pueden utilizarse como protección en instrumentación y como protección de circuitos auxiliares en ferrocarriles.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-weight: bold;"&gt;DF ELECTRIC&lt;/span&gt;&lt;br /&gt;&lt;a href="http://www.df-sa.es/"&gt;Expertos en protección eléctrica&lt;br /&gt;&lt;/a&gt;más información en &lt;a href="http://www.df-sa.es/"&gt;www.df-sa.es&lt;/a&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6727360867763117230-8194665202891289231?l=df-fusibles.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='related' href='http://www.df-sa.es/' title='Fusibles y Bases portafusibles para aplicaciones fotovoltaicas'/><link rel='replies' type='application/atom+xml' href='http://df-fusibles.blogspot.com/feeds/8194665202891289231/comments/default' title='Enviar comentarios'/><link rel='replies' type='text/html' href='http://df-fusibles.blogspot.com/2009/03/fusibles-y-bases-portafusibles-para.html#comment-form' title='0 comentarios'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6727360867763117230/posts/default/8194665202891289231'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6727360867763117230/posts/default/8194665202891289231'/><link rel='alternate' type='text/html' href='http://df-fusibles.blogspot.com/2009/03/fusibles-y-bases-portafusibles-para.html' title='Fusibles y Bases portafusibles para aplicaciones fotovoltaicas'/><author><name>incade</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='31' height='10' src='http://2.bp.blogspot.com/_1nznTXf7Xn4/TLVdCtiwjyI/AAAAAAAAAEU/WxkMDTztD4g/S220/logo-nextpaint-LR.jpg'/></author><thr:total>0</thr:total></entry></feed>
